No single compliance deadline is hard. The trouble is that a portfolio runs hundreds of them at once, each on its own clock. A gas record handed over late or a deposit protected on day 31 surfaces when it matters most: in a dispute, a council visit or a possession claim. This guide puts the recurring deadlines for a private let in England on one calendar, then sets out a routine that stops them slipping.

The calendar at a glance

Use this as the checklist for every tenancy. The sections below give the detail.

WhenWhat must happen
Before move-inRight to Rent check on every adult occupier (no earlier than 28 days before the agreement for a time-limited right). Give the new tenant the current gas safety record and electrical report. Have a valid EPC in place before marketing.
Day oneCheck every smoke and carbon monoxide alarm is in proper working order on the day a new tenancy begins.
Within 28 daysGive existing tenants a copy of each new gas safety record and each new electrical report. Finish any electrical remedial or investigative work (sooner if the report says so).
Within 30 days of taking a depositProtect it in an approved scheme and give the tenant the prescribed information.
YearlyGas safety check on every appliance and flue the landlord provides, at intervals of no more than 12 months.
Before a time-limited statutory excuse expiresRight to Rent follow-up check, and a report to the Home Office if the occupier cannot show a continued right.
Every 5 yearsElectrical inspection and test, or sooner if the last report sets an earlier date.
Every 10 yearsAn EPC lasts 10 years. Check it is still valid before each new marketing campaign or let.
End of tenancyReturn the deposit within 10 days of agreeing the amount. Keep Right to Rent evidence for at least a year after the tenancy ends.

Gas safety: every 12 months

Under regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, every gas appliance and flue the landlord provides must be checked within 12 months of installation and then at intervals of no more than 12 months. HSE is clear that a Gas Safe registered engineer carries out the check.

  • Early checks keep the date. Since the 2018 amendment, a check completed in the two months before the deadline is treated as if it was done on the deadline date (regulation 36A). Book renewals in that window and the anniversary never drifts earlier.
  • Copies to tenants. Existing tenants get a copy of the record within 28 days of the check. New tenants get the latest record before they move in. For a let of 28 days or less, the record can be displayed prominently in the property instead.
  • Records. Keep each record until two further checks have been done.

Electrical safety: every five years

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require a qualified person to inspect and test the electrical installation at intervals of no more than five years, or sooner if the latest report says so. Regulation 3 then sets a run of deadlines for copies of the report:

  • a copy of the report to each existing tenant within 28 days of the inspection;
  • a copy to a new tenant before they occupy the property;
  • a copy to a prospective tenant within 28 days of their written request;
  • a copy to the local housing authority within 7 days of its written request;
  • a copy to the person who carries out the next inspection.

Where the report calls for remedial or further investigative work, it must be done within 28 days of the inspection, or within any shorter period the report gives. You then need written confirmation from a qualified person that the work is done, and that confirmation goes, with the original report, to the tenants and the local housing authority within 28 days of the work being completed. Keep a copy of the report until the next inspection has been done.

Smoke and carbon monoxide alarms

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended in October 2022, set three duties:

  1. Smoke alarms. At least one on every storey that has a room used wholly or partly as living accommodation.
  2. Carbon monoxide alarms. One in any room used as living accommodation that contains a fixed combustion appliance. Gas cookers are excluded.
  3. Working order. Check each alarm is in proper working order on the day a new tenancy begins, and repair or replace any alarm once you are told it is faulty and find that it is.

A council can fine up to £5,000 where a landlord fails to comply with a remedial notice. Record the day-one test with the check-in paperwork.

Deposits: 30 days, then 10 days at the end

You (or your letting agency) must put the tenancy deposit in the Deposit Protection Service, mydeposits or the Tenancy Deposit Scheme within 30 days of receiving it, and give the tenant the prescribed information within the same 30 days. At the end of the tenancy, the deposit must be returned within 10 days of both sides agreeing how much the tenant gets back. If you cannot agree, the money stays protected and the scheme’s free dispute service decides.

The deadline matters long after day 30: since 1 May 2026, a landlord must show the deposit was protected and the prescribed information given before using most possession grounds. Our deposits guide has the full rules.

Right to Rent: before the tenancy, then follow-ups

Every adult who will live in the property as their only or main home needs a check before the tenancy begins, whatever their nationality. An unlimited right can be checked any time before the agreement. A time-limited right must be checked no earlier than 28 days before the agreement, then followed up before the statutory excuse runs out. Keep the evidence, with the date of the check, for the tenancy and at least one year after it ends. Our Right to Rent guide covers the 1 October 2026 changes.

Energy Performance Certificate

GOV.UK says you must order an EPC for prospective tenants before you market a property to rent, and the landlord or letting agent must show it to someone renting. An EPC is valid for 10 years, which makes it the easiest date to forget. Put it on the same calendar as the gas and electrical certificates, so an expired one never holds up a re-let.

Deadlines slip across a portfolio when dates live inside PDFs. Hold them as data against each property and open the renewal well before expiry.

How to stop deadlines slipping across a portfolio

  1. One record per property. Every certificate and its expiry date sit against the property, not in a shared folder or an email thread.
  2. Dates, not documents. Record a certificate’s dates the day it arrives. A PDF in an inbox is not a record anyone can search.
  3. Open renewals early. Raise the gas renewal inside the two-month window and the electrical renewal well before the five-year date, so access problems have time to resolve.
  4. Prove the hand-over. Log when and how each tenant received each record. The duty is to give the copy, so keep evidence of the sending.
  5. Review the exceptions weekly. Anything expired, anything due in 30 days, and anything with no date at all. The last group is usually the real risk.

This calendar covers private lets in England. Licensed HMOs meet the alarm duties through their licence conditions instead, and Wales and Scotland have their own rules. Check the specific property and tenancy before relying on any date.

Questions

Can a gas safety check be done early without losing the anniversary date?

Yes. A check completed in the two months before the deadline date is treated as if it was done on the deadline date, so the 12-month cycle keeps its original anniversary. Keep each record until two further checks have been done.

Can we send the gas safety record to tenants by email?

HSE says you can send it electronically if the tenant is happy with that and can open it, but you must give them a paper copy if they ask. Existing tenants need it within 28 days of the check, and new tenants before they move in.

Does a room with a gas cooker need a carbon monoxide alarm?

Not because of the cooker. The rule covers any room used as living accommodation that contains a fixed combustion appliance, and gas cookers are excluded. A room with a gas boiler or a wood-burning stove does need one.

Sources

  1. legislation.gov.uk: Gas Safety (Installation and Use) Regulations 1998, regulation 36
  2. legislation.gov.uk: Gas Safety (Installation and Use) Regulations 1998, regulation 36A
  3. HSE: Gas safety check records and what to keep
  4. HSE: Landlords, dealing with tenants
  5. legislation.gov.uk: Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, regulation 3
  6. GOV.UK: The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, Q&A booklet
  7. GOV.UK: Deposit protection schemes and landlords
  8. GOV.UK: Repossessing your privately rented property after 1 May 2026
  9. GOV.UK: Landlord’s guide to right to rent checks, 1 October 2026
  10. GOV.UK: Energy Performance Certificates
  11. GOV.UK: Renting out your property, landlord responsibilities

Checked against official sources on 27 October 2026. General information, not legal advice.